Metal faced ceiling access panel, fitted with unique Flipfix Fitting Device, Non fire rated , 25mm wide picture frame, No Lock , single door unit, circular door, powder coated RAL 9010 30% gloss, the dimension stated is the diameter of the panel
Minimum Size - 0200mm Dia
Maximum Size - 0600mm Dia
Make sure the structural opening is at least 5mm larger than the panel size, back of frame size. E.G a 600mm Diameter panel size requires a 605mm hole size. You don't need to remove the door, just open the panel using the budget lock key provided, place the panel into the aperture. Tighten the FlipFix device via the fixing screw behind the door leaf to clamp on the back of the plasterboard (The FlipFix device covers boards from 8mm to 32mm) Lock the door in place; the door and frame should be flush. Sit back and relax, you've just saved yourself 20 minutes.