Wall Access - 2 Hour Fire Rated From Both Sides - Smoke Tested - Robust Riser Door
ENQUIRE NOW
Wall Access Panel, Supplied with the Rapid Fit Hinge System, 1.2mm Thick Door Leaf, 1.5mm Thick Frame, 2 Hour Fire Rated, Metal Faced Door, 25mm wide Picture Frame, 3 Point Locking System, Single Door Unit, Smoke Tested, Powder Coated RAL 9010 30% Gloss, the 1st dimension stated is the hinge side.
This panel has a Fire Test Certificate up to 2400x900mm from the front & rear in a Wall application covered by Fire Certificate Number 503796 tested in accordance with BSEN 1634-1: 2014 + A1:2018. Anything above these sizes will be manufactured to the same construction as tested.
This Panel is Smoke tested covered by Certificate Number WYC504480 tested in accordance with BS EN 1634-3: 2004.
For Beaded Frame options
Wall Access Panel, Supplied with the Rapid Fit Hinge System, 1.2mm Thick Door Leaf, 1.5mm Thick Frame, 2 Hour Fire Rated, Metal Faced Door, 25mm wide Picture Frame, 3 Point Locking System, Single Door Unit, Smoke Tested, Powder Coated RAL 9010 30% Gloss, the 1st dimension stated is the hinge side.
This panel has a Fire Test Certificate up to 2400x900mm from the front & rear in a Wall application covered by Fire Certificate Number 503796 tested in accordance with BSEN 1634-1: 2014 + A1:2018. Anything above these sizes will be manufactured to the same construction as tested.
This Panel is Smoke tested covered by Certificate Number WYC504480 tested in accordance with BS EN 1634-3: 2004.
RapidFit Hinge System
120 Minutes Fire Rated From Both Sides
Picture Frame
Bespoke
Minimum Size - 0300 x 0300mm
Maximum Size Single Door - 2400x0900mm
Maximum Size Double Door - 2400x1800mm
Maximum Size 3 Door - 2400x2400mm
/contentfiles/files/Rapid%20Access%2051%20Range%20Riser%20Door%20Installation%20Guide(1).pdf
Make sure the structural opening is at least 7mm larger than the panel size, back of frame size. E.G a 600x600mm panel size requires a 607x607mm hole size. Remove the door from the frame and place the frame into the set hole. Fix through the appropriate fixing holes within the fold up fixing tabs ensuring the frame is pushed up against the structural opening surround. Check the frame is square by measuring corner to corner. Refit door and lock in place; the door and frame should be flush. Independent bracing or support may be required to take the weight of the Access Panel. Apply Intumescent acrylic mastic on both faces of the frame, nominally 5mm wide sealing to the supporting construction.
3 Way Lock
3 Point Euro Lock
5mm Bit
Key Retaining Lock