Metal Faced Ceiling Access Panel, Supplied with the Patented FlipFix Fitting Device, 2 Hour fire rated, 25mm wide Picture Frame, No Lock, Single Door Unit, Lift Out Door, Circular Door, Fitted with Safety Wires, Powder Coated RAL 9010 30% Gloss, the dimension stated is the diameter of the panel. This panel has a Fire Test Certificate up to 300mm Diameter in a Ceiling application covered by Fire Certificate Number 403948 tested in accordance with BSEN 1364-2:2018. Anything above these sizes will be manufactured to the same construction as tested.The Flipfix clamps must be used to fix this product into place to keep to the fire test requirements.
0200mm Dia Minimum Size - 0150mm Dia
0300mm Dia Maximum Size - 0600mm Dia
Make sure the structural opening is at least 5mm larger than the panel size, back of frame size. E.G a 600mm Diameter panel size requires a 605mm hole size. You don't need to remove the door, just open the panel using the budget lock key provided, place the panel into the aperture. Tighten the FlipFix device via the fixing screw behind the door leaf to clamp on the back of the plasterboard (The FlipFix device covers boards from 8mm to 32mm) Lock the door in place; the door and frame should be flush. Sit back and relax, you've just saved yourself 20 minutes.