Metal Faced Insulated Loft Hatch Ceiling Access Panel, 30 Minute fire rated, Metal Door, 25mm wide Picture Frame, 3 Point Locking System, Single Door Unit, Powder Coated RAL 7016 30% Gloss, the 1st dimension stated is the hinge side. This panel has a Fire Test Certificate up to 1200x900mm in a Ceiling application covered by Fire Certificate Number 422990 tested in accordance with BS EN 1634-2: 2018. Anything above these sizes will be manufactured to the same construction as tested.
Metal Faced Insulated Loft Hatch Ceiling Access Panel, 30 Minute fire rated, Metal Door, 25mm wide Beaded Frame, 3 Point Locking System, Single Door Unit, Powder Coated RAL 7016 30% Gloss, the 1st dimension stated is the hinge side. This panel has a Fire Test Certificate up to 1200x900mm in a Ceiling application covered by Fire Certificate Number 422990 tested in accordance with BS EN 1634-2: 2018. Anything above these sizes will be manufactured to the same construction as tested.
Minimum Size - 0300 x 0450mm
Maximum Size - 1000 x 1000mm
- Make sure the structural opening is at least 7mm larger than the panel size, back of frame size. (for example, a 600x600mm panel size requires a 607x607mm hole size).
- Remove the door from the frame and place the frame into the set hole.
- Fix through the appropriate fixing holes within the frame ensuring the frame is pushed up against the structural opening surround.
- Check the frame is square by measuring corner to corner.
- Refit door and lock in place; the door and frame should be flush.
- Independent bracing or support may be required to take the weight of the Loft Hatch.
- Apply Intumescent acrylic mastic on both faces of the frame, nominally 5mm wide sealing to the supporting construction.
THIS PRODUCT MUST BE INSTALLED INTO A VENTED ROOF SPACE.